The Method 5 Sampling Train Includes :
• Isokinetic Control Console.
• Modular Sample Unit (includes oven & impinger compartment).
• 826mm Glassware Set.
• Impinger Outlet.
• 10m, 20m or 40m Umbilical Cable.
• Probe Length Stocked 1/2 meter to 3 meters. Custom Length are Available.
• Set of Nozzles. (5mm, 7mm, 10mm, 12mm, 15mm, 20mm) (316ss, Quartz or Pyrex)
• Sample Recovery Kit.
• 826mm Glass Fibers Filters (Box of 100).
• Stainless Steel Port Adapter Seal Assembly.
Description :
The Clean Air Method 5 Train is suited to perform isokinetic particulate testing referencing US EPA 40 CFR 60, European prEN 13284-1. It is also compatible with Standard ISO 9096 for sampling particulates emissions from chimneys or smoke stacks. Condensable pollutants can be collected in the impingers per EPA Method 202.
A Method 5 Train is the basic equipment for stack testing. Ask your CleanAir Express customer service representive for more details on the accessories needed to perform EPA Methods 4, 5, 6, 23, 26, and 202 .
This equipments is also available separately.
Power Requirements :
120V AC or 240V available. The system 240V AC Train is CE certified
Transportation Weight:
4 to 5 Box. Total Weight Approximately 125 Kgs.
Guarantee :
The Method 5 Isokinetic Sampling Train with its accessories are guaranteed against manufacturing defects during a period of 15 months from date of delivery.
|